Hipure Viral Mini Column Spin Column

Product Details
Customization: Available
Material: PP
Product Name: Hipure Viral Mini Column
Still deciding? Get samples of US$ 1/Piece
Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
4
Year of Establishment
2021-01-29
  • Hipure Viral Mini Column Spin Column
  • Hipure Viral Mini Column Spin Column
  • Hipure Viral Mini Column Spin Column
  • Hipure Viral Mini Column Spin Column
  • Hipure Viral Mini Column Spin Column
  • Hipure Viral Mini Column Spin Column
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Detailed Photos
  • Certificate
  • Exhibition all over the world
  • Laboratory
  • Workshop
Overview

Basic Info.

Model NO.
C13112
Recommended Application
Small Amounts of Nucleic Acid Isolation, Viral Nuc
Preservation Conditions
Room Temperature
Stability
up to 4 Years
Filter Membrane
High Quality Glass Fiber Filter GF/F, 3 Layers
Membrane Aperture
0.7μm
Maximum Binding Yield of Plasmid
30 μg
Maximum Yield of Alcohol Mediated Bindin
200 μg
Single Liquid Carrying Capacity of Colum
800 μl
Minimum Elution Volume
30 μl
Withstand Centrifugal Force
16,000 X G
Centrifuge
Small High Speed Centrifuge (2ml)
Sample
Free Sample for Test
After-Sales Service
Technical Support
Shipping
FedEx, DHL, Door to Door
Transport Package
Box
Specification
2ml
Trademark
Magen Biotech
Origin
China
HS Code
3926909090

Product Description

Product Description

HiPure Viral Mini Column

CAT NO PRODUCT NAME SIZE PRICE
C13112 HiPure ViralMini Column 1000/Bag $320.00



△ Introduction

Magen's HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.

The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen's columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.



△ Details
 

Features Specifications
Recommended application Small amounts of nucleic acid isolation, viral nucleicacid from cell free samples
Preservation conditions Room temperature
Stability Up to 4 years
Filter membrane High quality glass fiber filter GF/F, 3 layers
Membrane aperture 0.7μm
Maximum binding yield of plasmid 30 μg
Maximum yield of alcohol mediated Binding 200 μg
Single liquid carrying capacity of column  800 μl
Minimum elution volume  30 μl
Withstand centrifugal force 16,000 x g
Centrifuge Small high speed centrifuge (2ml)



 Adsorption Mechanism

Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silicagel membrane, while other pollutants, mainly proteins, are removed by membrane washing.

 

△ Ordering information

CAT.No. Product Name Package
C13112 HiPure Viral Mini Column I (3 x GF/F)
with 2ml Collection Tubes

1000/Bag


 Purchase Guide

Item No. Product Name

Membrane type/number of layers

Collection tubes

Plasmid DNA binding capacity (Physical adsorption)

gDNA/RNA binding capacity (Alcohol-mediated adsorption)

Minimum Elution volume

Liquid volume capacity

C13010 HiPure DNA Nano Column 2 layers GF/F

2mlwithout cap

g 20μg 10μl 700μl
C13011 HiPure DNA Micro Column 3 layers GF/F

2mlwithout cap

10μg 50μg 15μl 700μl
C13100 HiPure DNA Mini Column I 2 layers GF/B

2mlwithout cap

15μg 100μg 30μl 700μl
C13110 HiPure DNA Mini Column II 4 layers GF/B

2mlwithout cap

35μg 200μg 50μl 800μl
C13111 HiPure RNA Mini Column 3 layers GF/B

2mlwithout cap

30μg 200μg 30μl 800μl
C13112 HiPure Viral Mini Column 3 layers GF/F

2mlwithout cap

30μg 200μg 30μl 800μl
C13113 HiPure CFDNA Mini Column 3 layers GF/F,1 layer GF/B

2mlwithout cap

30μg 200μg 30μl 800μl
C13120 HiPure DNA Midi Column 4 layers GF/B

15mlCentrifuge tube

125μg 1mg 500μl 4ml
C13121 HiPure DNA Midi Column III 8 layers GF/B

15mlCentrifuge tube

250μg 1mg 500μl 4ml
C13122 HiPure DNA Maxi Column 4 layers GF/B

50mlCentrifuge tube

500μg 5mg 1000μl 20ml
C13123 HiPure DNA Maxi Column III 8 layers GF/B

50mlCentrifuge tube

1mg 5mg 1000μl 20ml
C13124 HiPure DNA Maxi Column C 8 layers GF/B

50ml high speedCentrifuge tube

1mg 5mg 700μl 12ml
C13130 HiPure DNA Plate 2 layers GF/F 1.6ml Plate 30μg 100μg 80μl 900μl
C13131 HiPure gDNA Plate 2 layers GF/B 1.6ml Plate 30μg 100μg 80μl 900μl

 

Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
 
Company Profile

Hipure Viral Mini Column Spin ColumnHipure Viral Mini Column Spin ColumnHipure Viral Mini Column Spin ColumnHipure Viral Mini Column Spin Column


 
Detailed Photos

Hipure Viral Mini Column Spin Column

Certificate

Hipure Viral Mini Column Spin ColumnHipure Viral Mini Column Spin ColumnHipure Viral Mini Column Spin Column

 

Exhibition all over the world

Hipure Viral Mini Column Spin ColumnHipure Viral Mini Column Spin Column

Laboratory

Hipure Viral Mini Column Spin Column
 

Workshop

Hipure Viral Mini Column Spin Column
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier