15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane

Product Details
Customization: Available
Material: PP
Recommended application: Plasmid Medium Yield preparation
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
4
Year of Establishment
2021-01-29
  • 15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane
  • 15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane
  • 15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane
  • 15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane
  • 15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane
  • 15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Protocol
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
C13121
Preservation conditions
Room temperature
Stability
Up to 4 years
Filter membrane
High quality glass fiber filter GF/B, 8 layers
Membrane aperture
1.0 μm
Maximum binding yield of plasmid
250 μg
Maximum yield alcohol mediated Binding
1 mg
Plasmid Yields
Up to 0.25mg
Single liquid carrying capacity column
4 ml
Minimum elution volume
500 μl
Withstand centrifugal force
5,000 x g
Centrifuge1
Lowspeed centrifuge for 15ml centrifuge tubes
Centrifuge2
>3000 x g, swing-out Rotor, or Fixed Angle Rotor
Transport Package
Box
Specification
100pcs / bag
Trademark
Magen Biotech
Origin
China
HS Code
3926909090

Product Description

Product Description

 

HiPure DNA Midi Column III

CAT NO PRODUCT NAME SIZE PRICE
C13121 HiPure DNA Midi Column III 100/Bag $572.00


Magen's HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.

The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen's columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.

 

 

Specifications

Features Specifications
Recommended application Plasmid Medium Yield preparation
Preservation conditions Room temperature
Stability Up to 4 years
Filter membrane High quality glass fiber filter GF/B, 8 layers
Membrane aperture 1.0 μm
Maximum binding yield of plasmid 250 μg
Maximum yield of alcohol mediated Binding 1 mg
Plasmid Yields Up to 0.25mg
Single liquid carrying capacity of column 4 ml
Minimum elution volume 500 μl
Withstand centrifugal force 5,000 x g
Centrifuge Lowspeed centrifuge for 15ml centrifuge tubes, >3000 x g, swing-out Rotor, or Fixed Angle Rotor

 

 

 



Adsorption Mechanism

Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silica gel membrane, while other pollutants, mainly proteins, are removed by membrane washing.




Ordering information
CAT.No. Product Name Package
C13121 HiPure DNA Midi Column III (8 x GF/B)
with 15ml Collection Tubes
100/Bag



Purchase Guide
Item No. Product Name

Membrane type/number of layers

Collection tubes

Plasmid DNA binding capacity (Physical adsorption)

gDNA/RNA binding capacity (Alcohol-mediated adsorption)

Minimum Elution volume

Liquid volume capacity

C13010 HiPure DNA Nano Column 2 layers GF/F

2ml without cap

g 20μg 10μl 700μl
C13011 HiPure DNA Micro Column 3 layers GF/F

2ml without cap

10μg 50μg 15μl 700μl
C13100 HiPure DNA Mini Column I 2 layers GF/B

2ml without cap

15μg 100μg 30μl 700μl
C13110 HiPure DNA Mini Column II 4 layers GF/B

2ml without cap

35μg 200μg 50μl 800μl
C13111 HiPure RNA Mini Column 3 layers GF/B

2ml without cap

30μg 200μg 30μl 800μl
C13112 HiPure Viral Mini Column 3 layers GF/F

2ml without cap

30μg 200μg 30μl 800μl
C13113 HiPure CFDNA Mini Column 3 layers GF/F,1 layer GF/B

2ml without cap

30μg 200μg 30μl 800μl
C13120 HiPure DNA Midi Column 4 layers GF/B

15ml Centrifuge tube

125μg 1mg 500μl 4ml
C13121 HiPure DNA Midi Column III 8 layers GF/B

15ml Centrifuge tube

250μg 1mg 500μl 4ml
C13122 HiPure DNA Maxi Column 4 layers GF/B

50ml Centrifuge tube

500μg 5mg 1000μl 20ml
C13123 HiPure DNA Maxi Column III 8 layers GF/B

50ml Centrifuge tube

1mg 5mg 1000μl 20ml
C13124 HiPure DNA Maxi Column C 8 layers GF/B

50ml high speed Centrifuge tube

1mg 5mg 700μl 12ml
C13130 HiPure DNA Plate 2 layers GF/F 1.6ml Plate 30μg 100μg 80μl 900μl
C13131 HiPure gDNA Plate 2 layers GF/B 1.6ml Plate 30μg 100μg 80μl 900μl

 

Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.

Detailed Photos

15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane

Protocol

15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane

Company Profile

15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane15ml Hipure DNA Midi Column III 8 layers glass fiber filter membrane

FAQ

Q1.What is the Trade Term?
A1:Ex-work factory (Guangzhou)

Q2. How long is the guarantee (period)?
A2:The product can be stored properly for at least 18 months .

Q3.Are you a manufacturer
A3:Yes, we were established in 2012 and our headquarter is in Guangzhou. All products can be provided with OEM packaging, greatly reduce the cost, and can be flexible in technology and other aspects of communication and cooperation.


Q4.How long is our Production leading time?
A4:Generally our lead time is 2-7 working days after receiving 100% prepayment. If order in bulk , lead time will be longer. Customized bulk quantities are determined by the specific quantity.


Q5.What is the Payment term?
A5:T/T, Paypal, Alipay, Western Union. 100% payment in advance.

Q6.What is the packing details?
A6:The outer packaging of general products is cardboard boxes. Low-temperature products will have ice packs places in foam boxes and then packed into cartons.

Q7. What support you will have to assemble this extractor?
A7: Our extraction instrument is integrated, easy to operate and does not require assembly.

Q8.What kind of documents we will provide to you?
A8:B/L or AWB number, Commercial Invoice, Packing List, MSDS, COA.


Q9. How to apply the free samples?
A9: For free samples we have to know your company name, your E-mail, your FedEx account, and the detail address of your company include the phone number. You can contact with us to apply the free samples.

Q10. Do you accept the small orders?
A10: Yes, we accept the small orders. We will try our best to support our customer's business whether the small trail order.

 





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier